A signal is a named value that Visual Radio Assist and your own systems both read and write, like a tally or a GPI. Use it to take automation out for an item from a Stream Deck, a dashboard or your own system, and to give it back. Every studio comes with two signals, and with a Pro license you add your own. Signals live in Settings → Studio → Signals.

How signals work

  1. A signal has a value: on or off, a number or a text.
  2. Something sets that value: a dashboard button, the Signals page, a control surface through the Core API, or a VRA product.
  3. VRA reacts to it: the default signals switch automation on or off, and an automation can check any signal in its conditions.
Each signal remembers what set it last and when, so you can see why automation stopped.

The default signals in every studio

Every studio has two default signals. They come with every license, belong to their own studio and cannot be deleted. You can rename a default signal and turn it on or off, but its scope, identifier and value type are fixed, so one studio never switches off automation in another.

Turn a signal on or off

To turn a signal on or off in VRA Cloud, open Settings → Studio → Signals, click the dots next to the signal and pick Turn on or Turn off. To set a number or a text, click the signal, enter the value under Current value and click Set. Only input signals that are enabled can be set. An output signal is set by VRA, and its value is read only. On air, a Signal button on a dashboard or a key on a Stream Deck with Bitfocus Companion is quicker than the settings page.

Add your own signal

Your own signals need a Pro license. With a lower license, Add signal is unavailable and the two default signals still work. To add a signal, open Settings → Studio → Signals and click Add signal. Fill in the settings and click Create signal. After you create a signal, its sheet also shows Enabled. When Enabled is off, the signal keeps its value, but nothing can write it.

Use a signal in an automation

To run a command when a signal has a value, add the Signal state condition to an automation, pick the signal and the value. A station wide signal shows with (station wide) after its name. Deleting a signal stops every condition that uses it. The Signals page shows how many conditions use a signal, and the delete confirmation says so again.

Set a signal from outside VRA

The Core API v2 reads and writes signals from a control surface or a script on the studio network, by id or by identifier. For example, /api/v2/signals/audio-director/off switches off audio auto switching for the studio. The same routes work over TCP and OSC.

Limitations

  • Signals cannot be added below a Pro license. The two default signals work on every license.
  • A default signal cannot be deleted, moved to another studio or changed to another value type.
  • An output signal cannot be written from a dashboard, the Signals page or the Core API.